Low Level Sodium Analyzer HK-358 

 - Applications:
 + Power
 + Chem or Petrochemical 
 + Pulp and Paper 
 + Semiconductor 
 + Ultra pure water anakysis,boiler feed waterion exchange breakthrough,steam analysis,drum boiler water

 - Features 
 + Sensitivity to ppb range
 + Advanced embedded MCU technology,SMT and integrative design
 + Panel mount,aluminum enclosure anti-interference
 + 192×64 lattice LCD display
 + User interface language:English
 + Simultancous display of multtiparameters
 + Automatic or manual temperature compensation
 + Two analog outputs and two alarm relay outputs
 + CAN bus communication
 + Large datalog of previous measurements and trend curve trackable
 + Universal power supply for worldwide operation(100~240)V
 + Low reagent consumption
 + Fast response,accurate measurement ease-of-use with minimal maintenance

Specifications

TRANSMITTER
 - Measurement Range : (0.00 to 9.36)pNa, 0.01μg/L to 23.0g/L, (-1.000 to +1.000)mV
 - Resolution (min) : 0.01pNa, 0.01ug/L, 0.1mV
 - Accuracy : 0.01pNa, 1character, ±0.5mV (during ±10oC of the calibration temperature)
 - Stability : ±0.01pNa/24h, ±1character/24h, ±0.5mV/24h
 - Analog Output : (0~10)mA or (0~20)mA or (4~20)mA,two isolated outputs
 - Output Accuracy : ±1%F.S
 - Max.load Resistance : ≤800W
 - Power Supply : (100~240)VAC, (45~65)Hz
 - Power Consumption : ≤8W
 - Insulation Strength : Power to ground 1500V, no flying arc in 1 min
 - Alarm Output
 +   : Two alarm relays. Each relay can be configured as: high and low concentration alarm, high and low temperature alarm. 
 +   : One relay can be simultaneously selected by two alarms. 
 +   : If anyone of the two alarms occurs, it will be activated.
 - Communication : CAN Bus (option)
 - Data Logger : Record measurement values, history events and calibration results

INSTRUMENT
 - Measurement Range : (1.00-8.00)pNa, 0.23ug/L-2300mg/L
 - Resolution (min) : 0.01pNa or 0.01ug/L
 - Accuracy
 +   : ±0.02pNa or ±0.5ug/L ( the larger one), 
 +   : whichever is greater (between ±10oC of calibration temperature) 
 - Response Time (T90) : ≤2 min at 25oC
 - Temperature Sensor : Pt1000
 - Temperature Range : (0.0 to 99.9)oC
 - Temperature Accuracy : ±0.5 oC
 - Temperature Compensation : (0.1 to 60.0)oC (auto or manual)
 - Calibration Method : Sample calibration and standard solution calibration
 - Overall Dimension (mm) : 450(L) × 690(W) × 190(D)
 - Cutout Dimensions (mm) : 410 × 645
 - Weight : 19kg 
 - Sample Condition
 +   : Temperature: (5 to 50)oC
 +   : Pressure: (50-300)KPa 
 +   : Flow: (6-40)L/h
 +   : Solid contents in sample: ≤5mm (no gel and grease)
 - Ambient Temperature :  (5 to 45)oC
 - Ambient Humidity : ≤90%RH (no condensation)
 - Storage Temperature :  (-25 to 55)oC (above 0oC for electrode)